Creator | Heiner, Bryan J. Barfuss, Steve L. Johnson, Michael C. |
Description | A study conducted by the Utah Water Research Laboratory assessed the accuracies of a wide variety of flow measurement devices currently in service. During the study, a wide variety of flow measurement devices, including flumes, weirs, and rated sections in open channel systems, were evaluated; magnetic and ultrasonic meters in closed-conduit systems were also tested. The specified design accuracies for each device are presented. Actual flow measurements were determined at 70 sites and were... |
Date | 2011-06-01T07:00:00Z |
Type | text |
Identifier | https://digitalcommons.usu.edu/cee_facpub/2003 info:doi/10.1061/(ASCE)IR.1943-4774.0000309 |
Rights | Copyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact the Institutional Repository Librarian at digitalcommons@usu.edu. |