Record Details

Comparing Low Flow Accuracy of Mechanical and Electronic Meters

DigitalCommons@USU

Field Value
Title Comparing Low Flow Accuracy of Mechanical and Electronic Meters
Creator Sumrak, McKenna L. Johnson, Michael C. Barfuss, Steve L.
Description Previous studies have identified water meter inaccuracy at low flows in mechanical metering technologies; however, little has been done to measure the inaccuracy of electronic metering technologies at low flows. This study confirms previous studies on mechanical meter accuracy and includes electronic meter accuracy data from results of testing conducted at the Utah Water Research Laboratory. By comparing the new technologies to the commonly used mechanical metering technologies over a wide...
Date 2016-06-01T07:00:00Z
Type text
Identifier https://digitalcommons.usu.edu/cee_facpub/1976 info:doi/10.5942/jawwa.2016.108.0069
Rights Copyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact the Institutional Repository Librarian at digitalcommons@usu.edu.
Source Civil and Environmental Engineering Faculty Publications
Publisher Hosted by Utah State University Libraries
Contributor American Water Works Association
Subject Civil and Environmental Engineering

© Western Waters Digital Library - GWLA member projects - Designed by the J. Willard Marriott Library - Hosted by Oregon State University Libraries and Press