Title Effects of Pipe Wall Offsets on Differential Pressure Meter Accuracy
Creator Pope, Jesse M. Barfuss, Steve L. Johnson, Michael C. Sharp, Zachary B.
Description Accurate flow measurement is essential for the management of any type of fluid system. This research investigated the effect on accuracy that five types of 12-in. differential-pressure flow meters have as a result of being installed in pipelines of differing inside diameter. The types of meters chosen for this research were the classical Venturi meter, Halmi Venturi Tube, wedge meter, V-cone meter, and the X-meter. Each meter was tested for accuracy with 10 pipe wall offsets varying from a...
Date 2015-06-01T07:00:00Z
Type text
Format application/pdf
Identifier https://digitalcommons.usu.edu/cee_facpub/1620 info:doi/10.5942/jawwa.2015.107.0081 https://digitalcommons.usu.edu/context/cee_facpub/article/2620/viewcontent/jaw201506pope_pr.pdf
Rights Copyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact the Institutional Repository Librarian at digitalcommons@usu.edu.
Source Civil and Environmental Engineering Faculty Publications
Publisher Hosted by Utah State University Libraries
Contributor American Water Works Association
Subject UWRL Civil and Environmental Engineering Engineering