Record Details

A five-year performance review of field-scale, slow-release permanganate candles with recommendations for second-generation improvements

University of Nebraska - Lincoln Digital Commons

Field Value
Title A five-year performance review of field-scale, slow-release permanganate candles with recommendations for second-generation improvements
Creator Christenson, Mark Kambhu, Ann Reece, James Comfort, Steve D. Brunner, Laurie
Description In 2009, we identified a TCE plume at an abandoned landfill that was located in a low permeable siltyclay aquifer. To treat the TCE, we manufactured slow-release potassium permanganate cylinders (oxidant candles) that had diameters of either 5.1 or 7.6 cm and were 91.4 cm long. In 2010, we compared two methods of candle installation by inserting equal masses of the oxidant candles (7.6-cm vs 5.1-cm dia). The 5.1-cm dia candles were inserted with direct-push rods while the 7.6-cm candles were...
Date 2016-02-01T08:00:00Z
Type text
Format application/pdf
Identifier https://digitalcommons.unl.edu/watercenterpubs/29 https://digitalcommons.unl.edu/context/watercenterpubs/article/1028/viewcontent/Comfort_CHEMOSPHERE_2016_A_five_year__DC_VERSION.pdf
Source Faculty Publications from The Water Center
Publisher DigitalCommons@University of Nebraska - Lincoln
Subject Second-generation permanganate candles Chlorinated solvents TCE Slow-release oxidants Permeable reactive barrier Civil and Environmental Engineering Civil Engineering Environmental Engineering Environmental Sciences Hydraulic Engineering Other Civil and Environmental Engineering Other Operations Research, Systems Engineering and Industrial Engineering