A charge sensitive amplifier for use with piezoelectric transducers

ScholarsArchive at Oregon State University

Field Value
Title A charge sensitive amplifier for use with piezoelectric transducers
Names Magnuson, Waldo George (creator)
Stone, Louis N. (advisor)
Date Issued 1963-05-06 (iso8601)
Note Graduation date: 1963
Abstract The design of a preamplifier for use with a
piezoelectric transducer is generally approached from
the point of view that an extremely high input impedance
is required to obtain low frequency response.
However, piezoelectric transducers are essentially
charge generators and this fact may be utilized in designing
preamplifiers to be used with them. In this
thesis the concept of a charge amplifier is discussed
and a practical expression is derived in terms of frequency
response, input impedance, amplifier gain, and
feedback capacitor value. It is shown that modest input
impedances may be used and low frequency response
maintained, using this concept. A practical amplifier
design is illustrated and its performance is described.
Genre Thesis/Dissertation
Topic Amplifiers (Electronics)
Identifier http://hdl.handle.net/1957/49920