Record Details
Field | Value |
---|---|
Title | Fielding Ditch Pipeline Computer Simulation Study |
Creator | Clyde, Calvin G. Tullis, J. Paul Jeppson, Roland W. |
Description | The Fielding Ditch Company Pipeline is almost 3 miles long and supplies irrigation water under low pressure to adjacent fields through 33 turnouts along its length. The 24-inch non-reinforced concrete pipeline began to experience repeated structural failures soon after it was placed in operation. This study was done for the Soil Conservation Service by the Utah Water Research Laboratory to gather field data on the... |
Date | 1981-01-01T08:00:00Z |
Type | text |
Format | application/pdf |
Identifier | https://digitalcommons.usu.edu/water_rep/528 https://digitalcommons.usu.edu/context/water_rep/article/1527/viewcontent/Fielding_20Ditch_20Pipeline_20Computer_20Simulation_20Study.pdf |
Source | Reports |
Publisher | Hosted by Utah State University Libraries |
Subject | Civil and Environmental Engineering Water Resource Management |