Record Details
Field | Value |
---|---|
Title | The Kinetics of Rotating Biological Contactors Treating Domestic Wastewater |
Creator | Pano, Abraham Middlebrooks, E. Joe Reynolds, J. H. |
Description | Four, four-stage, laboratory scale rotating biological contactor (RBC) units were employed to develop kinetic models for the RBC process when treating domestic wastewater. The study was conducted at three different temperatures of 5 degrees C, 15 degrees C, and 20 degrees C. Each unit operated at a different constant organic loading rate taht ranged from 4 qCOD/m^2/d to 14 gCOD/m^2/d and at a constand detention... |
Date | 1981-01-01T08:00:00Z |
Type | text |
Format | application/pdf |
Identifier | https://digitalcommons.usu.edu/water_rep/167 https://digitalcommons.usu.edu/context/water_rep/article/1166/viewcontent/The_20Kinetics_20of_20Rotating_20Biological_20Contactors_20Treating_20Dome.pdf |
Source | Reports |
Publisher | Hosted by Utah State University Libraries |
Subject | Civil and Environmental Engineering Water Resource Management |